GET A QUOTE

RSV IgG ELISA Kit (Respiratory Syncytial Virus)

Home ELISA Kits Viral Diseases ELISA Kits RSV IgG ELISA Kit

£430

Kit Size
96 Wells
Sensitivity
1.22 U/ml
Availability
● In Stock

Order Now
● Ships within 5–7 working days

5.0



Based on 10 reviews

Highly rated by researchers for reliability, and ease of use.

✓ Reliable results
✓ Easy protocol
✓ Tight replicates
✓ Great sensitivity
✓ Fast delivery
✓ Knowledgeable support

INTENDED USE

Human RSV IgG ELISA kit is a procedure designed for detecting in-vitro amounts of human IgG antibodies to respiratory syncytial virus (RSV IgG) using samples of plasma or serum. This assay has a minimum analytical sensitivity limit of 1.22 U/ml.

BACKGROUND

Respiratory syncytial virus (RSV) is a member of the family Pneumoviridae, it is a negative sense, single stranded RNA virus causing infections of the lungs and the respiratory tract. It contains a lipoprotein coat and a linear negative-sense RNA genome (approx. 15,000 nucleotides in length). There are four viral genes N (nucleoprotein), P (phosphoprotein), M (matrix protein) and L (“large” protein), all of these are responsible for coding for intracellular proteins that are important for processes like transcription, replication and particle budding.

RSV virus can be transmitted via large droplets or through secretions from contact with infected individuals. ELISA assay’s are frequently used for serological diagnosis of RSV infections, they offer specificity, sensitivity and allow differentiation of antigens into their specific immunoglobulin classes.

CONTENT

All reagents supplied need to be stored at 2 °C – 8 °C, unopened reagents will retain reactivity until expiration date. Do not use reagents beyond this date.

  • Respiratory syncytial virus (RSV) antigen coated microtiter strips.
  • Enzyme Conjugate.
  • Sample Diluent.
  • TMB Substrate.
  • Washing Buffer (10x).
  • Stop Solution.
  • Negative Control (Calibrator A).
  • Cut-Off Standard (Calibrator B).
  • Positive Control (Calibrator D).
  • Weak Positive Control (Calibrator C).

SENSITIVITY

The minimum detection sensitivity level of IgG antibodies to respiratory syncytial virus (RSV-IgG) using current RSV IgG ELISA kit was 1.22 U/ml. The dynamic range for this assay is 1.0 – 150.0 U/ml.

ASSAY CHARACTERISTICS

– Intra-Assay-Precision: 6.4 %
– Inter-Assay-Precision: 10.7 %
– Inter-Lot-Precision: 4.8 – 12.1 %
– Analytical Sensitivity: 1.22 U/mL
– Recovery: 97 – 110 %
– Linearity: 70 – 117 %
– Cross-Reactivity: No cross-reactivity to Influenza A, Parainfluenza 1/2/3 and Adenovirus.
– Interferences: No interferences to triglycerides up to 5.0 mg/mL, bilirubin up to 0.3 mg/mL and hemoglobin up to 8.0 mg/mL.
– Clinical Specificity: 100 %
– Clinical Sensitivity: 100 %

REFERENCES

  1. Development of a luciferase immunoprecipitation system assay to detect IgG antibodies against human respiratory-syncytial virus nucleoprotein. Clin Vaccine Immunol. (2014) 21 (3): 383-90. Kumari S., et al.
  2. Antibody response and avidity of respiratory syncytial virus specific total IgG, IgG1, and IgG3 in young children. J Med Virol. (2011) 83 (10): 1826-33. Freitas G.R., et al.
  3. Seroprevalence of anti-RSV IgG in Thai children aged 6 months to 5 years. Asian Pac J Allergy Immunol. (2003) 21 (4): 269-71.
  4. [The standardization of an ultramicro ELISA assay for the detection of IgG antibodies to the respiratory syncytial virus]. Rev Cubana Med Trop. (1996) 48 (3): 161-2. Spanish. Savón C., et al.

ADDITIONAL INFORMATION

  • Full Name: RSV IgG ELISA Kit (Respiratory Syncytial Virus)
  • Reactivity: Human
  • Sample Type: Serum, Plasma
  • Sensitivity: 1.22 U/ml

OTHER RELATED ELISA KITS

Ready to order or need technical advice?

All kits in stock are shipped within 5–7 working days. Our technical team is available Monday to Friday.

Contact Us

Online Enquiry Form

"*" indicates required fields

Please check mark information required:

TESTIMONIALS arrow icon

Your secretory IgA ELISA gave good results and I was also really impressed with how quickly we received it.

L. Johnston
PhD Student / University of Glasgow

It is refreshing to know that you have a technical team that is very knowledgeable. I have already recommended your company to other researchers in our department.

Dr. P. Anderson
Lecturer / University College London (UCL)

I am a first time user and found that your instruction manual was very easy to follow. The insulin ELISA assay performed well and I was happy with the results that were generated.

J. Thomas
Senior Technician / Addenbrooke’s Hospital

I carried out a pilot study comparing the performance of many ELISA assay's from different suppliers and found your kits to be one of the better performers. We observed good linearity and tight replicates.

Dr. C. Davies
Lead Scientists / AstraZeneca

You are my first point of contact when I am looking to purchase ELISA. You have such an easy and simple system, yet it is very effective.

A. Shaw
Purchasing / University of Oxford