RNP 70 Ab ELISA Kit (Ribonucleoprotein 70)

Full Name: RNP 70 Ab ELISA Kit (Ribonucleoprotein 70)
Reactivity: Human
Sample Type: Plasma, Serum
Sensitivity: 1.0 U/ml

BACKGROUND

Autoantibodies directed against ribonucleoprotein 70 (RNP-70) have been important for the serological detection of Sharp syndrome (MCTD – Mixed Connective Tissue Disease), it is essentially a 70kDa protein which is part of the U1-snRNP complex. The sensitivity of this is 100%, meaning that MCTD can be completely ruled out if the autoantibodies are absent. However, some patients with SLE and systemic sclerosis are also found to test positive for anti-RNP. In general, patients only displaying antinuclear antibodies against the this protein tend to have the classical MCTD, whereas, other SLE-typical autoantibodies (for example anti-Sm, dsDNA and anti-histone) are found this indicates transition into SLE. Anti-RNP are antinuclear antibodies which belong to the extractable nuclear antigen antibodies (ENA) subset and these are directed against the U1-ribonucleoprotein of the ribonucleoprotein multi-enzyme complex.

INTENDED USE

Human RNP 70 Ab ELISA kit is intended for measuring in-vitro quantitative levels of IgG autoantibodies to ribonucleoprotein 70 (RNP-70, anti-RNP 70, RNP-70 Ab) in human serum or plasma samples. This assay has a minimum analytical sensitivity limit of 1.0 U/ml.

CONTENT

All reagents supplied need to be stored at 2 °C – 8 °C, unopened reagents will retain reactivity until expiration date. Do not use reagents beyond this date.

  • Divisible Microplate: Consisting of 12 modules of 8 wells, purified RNP-70 is bound to microwells.
  • Calibrator A-F: Concentrations 0, 12.5, 25, 50, 100, 200 U/ml, made up from ribonucleoprotein 70.
  • Control Positive and Control Negative: Containing human anti-RNP 70 antibodies in a serum/buffer matrix.
  • Sample Buffer (5x).
  • Enzyme Conjugate: Contains anti-human IgG antibodies, HRP labelled.
  • Substrate: 3,3’, 5,5’- Tetramethylbenzidin (TMB).
  • Stop Solution.
  • Wash Buffer (50x).
  • Certificate of Analysis.
  • Instruction for Use.

SENSITIVITY

The minimum detection sensitivity level of human IgG antibody to ribonucleoprotein 70 (RNP-70 IgG, RNP 70 Ab) using current RNP-70 Ab ELISA kit was 1.0 U/ml. The dynamic range for this assay is 12.5 – 200.0 U/ml.

ASSAY CHARACTERISTICS

– Limit Of Detection (LOD): Functional sensitivity was 1 U/ml.
– Measuring Range: 0 – 200 U/ml
– Linearity: 97 – 100%
– Expected Values: Cut-off 25 U/ml.
– Results Interpretation: Negative: < 25 U/ml, Positive: ≥ 25 U/ml.
– Intra Assay Precision: 3.9 – 5.8%
– Inter Assay Precision: 4.9 – 5.2%
– Interference: None.
– Clinical Diagnosis: Sensitivity (66.0%), Specificity (95.8%), Overall agreement (82.3%).

REFERENCES

  1. Autoantibody recognition of distinctly modified forms of the U1-70-kd antigen is associated with different clinical disease manifestations. Arthritis Rheum. (2000) 43 (4): 881-8. Greidinger E.L., et al.
  2. Identification of human Sm and (U1) RNP antigens by immunoblotting. J Immunol Methods. (1983) 64 (1-2): 45-59. Guldner H.H., et al.
  3. Human autoantibodies against the 70-kd polypeptide of U1 small nuclear RNP are associated with HLA-DR4 among connective tissue disease patients. Arthritis Rheum. (1990) 33 (5): 666-73. Hoffman R.W., et al.
  4. Anti-Sm and anti-RNP antibodies. Autoimmunity. (2005) 38 (1): 47-54. Review. Migliorini P., et al.
  5. T cell vaccination therapy in an induced model of anti-RNP autoimmune glomerulonephritis. Clin Immunol. (2010) 137 (2): 281-7. Trivedi S., et al.

OTHER RELATED ELISA KITS

Online Enquiry Form

"*" indicates required fields

Please check mark information required:

TESTIMONIALS arrow icon

Your secretory IgA ELISA gave good results and I was also really impressed with how quickly we received it.

L. Johnston
PhD Student / University of Glasgow

It is refreshing to know that you have a technical team that is very knowledgeable. I have already recommended your company to other researchers in our department.

Dr. P. Anderson
Lecturer / University College London (UCL)

I am a first time user and found that your instruction manual was very easy to follow. The insulin ELISA assay performed well and I was happy with the results that were generated.

J. Thomas
Senior Technician / Addenbrooke’s Hospital

I carried out a pilot study comparing the performance of many ELISA assay's from different suppliers and found your kits to be one of the better performers. We observed good linearity and tight replicates.

Dr. C. Davies
Lead Scientists / AstraZeneca

You are my first point of contact when I am looking to purchase ELISA. You have such an easy and simple system, yet it is very effective.

A. Shaw
Purchasing / University of Oxford