GET A QUOTE

HGF ELISA Kit

INTENDED USE

Human HGF ELISA kit is a reliable quantitative procedure for measuring hepatocyte growth factor (HGF) in human serum, tissue homogenates, plasma and biological fluids. This assay has a minimum sensitivity detection limit of 75.0 pg/ml.

BACKGROUND

Hepatocyte growth factor (HGF) is also be called scatter factor (SF), a paracrine motility, morphogenic and cellular growth factor that is secreted in an inactive single peptide form which can be cleaved by a serine proteases to form an alpha-chain (69kDa) and a beta-chain (34 kDa). The active form is generated as a result of a disulfide bond between the alpha and beta chains to give a heterodimeric molecule.

HGF protein is a member of the plasminogen subfamily of S1 peptidases but does not possess any detectable protease activity. It is found to be secreted by mesenchymal cells and known to target and act primarily on either endothelial or epithelial cells, however, there is some evidence that human HGF may also act upon T cells or haemopoietic progenitor cells. Hepatocyte growth factor have a major role in wound healing and in embryonic organ development (especially myogenesis during organ regeneration in adults). Furthermore, human HGF has the ability to stimulate matrix invasion, cell motility and mitogenesis indicates that it may have a key role tissue regeneration, tumorogenesis and angiogenesis. The gene that encodes the human hepatocyte growth factor is found to be linked to human chromosome 7.

HGF ELISA KIT CONTENT

All reagents supplied need to be stored at 2 °C – 8 °C, unopened reagents will retain reactivity until expiration date. Do not use reagents beyond this date.

  • One 96-Well Plate: Pre-coated with anti HGF antibody.
  • Standards: Concentrations 0, 125, 250, 500, 1000, 2000, 4000, 8000 pg/ml, made up from lyophilized recombinant human hepatocyte growth factor (HGF).
  • Sample/Standard Dilution Buffer.
  • Biotinylated-labelled HGFAntibody.
  • Antibody Dilution Buffer.
  • HRP-Streptavidin Conjugate (SABC).
  • SABC Dilution Buffer.
  • TMB Substrate.
  • Wash Buffer (25x).
  • Plate Sealer.
  • Product Instructions.

SENSITIVITY

The minimum sensitivity detection limit of hepatocyte growth factor (HGF) using current human HGF ELISA kit was approximately 75.0 pg/ml. The dynamic range for this assay is 125.0 – 8000.0 pg/ml.

ASSAY CHARACTERISTICS

– Hepatocyte Growth Factor (HGF): ELISA
– Specificity: Highly specific for detecting hepatocyte growth factor no cross reactivity or interference between other HGF analogues was detected.
– Recovery: Serum (89 – 101%), EDTA Plasma (90 – 104%), Heparin Plasma (86 – 96%).
– Linearity: Serum (86 – 105%), EDTA Plasma (85 – 101%), Heparin Plasma (83 – 100%).
– Precison Intra-Assay: CV < 8%.
– Precison Inter-Assay: CV < 10%.
– Stability: Less than 10% within the expiration date.

REFERENCES

  1. Localization of hepatocyte growth factor (HGF) gene on human chromosome 7. Genomics (1992) 12: 147-150. Zarnegar, R., et al.
  2. Molecular cloning and expression of human hepatocyte growth factor. Nature (1989) 342: 440-443. Nakamura, T., et al.
  3. A broad-spectrum human lung fibroblast-derived mitogen is a variant of hepatocyte growth factor. Proc. Nat. Acad. Sci. (1991) 88: 415-419. Rubin, J. S., et al.
  4. Localisation of hepatocyte growth factor and its receptor (c-met) protein and mRNA in human term placenta. Growth Factors (1996) 13: 133-139. Kilby, M. D. et al.

ADDITIONAL INFORMATION

  • Full Name: HGF ELISA Kit
  • Reactivity: Human
  • Sample Type: Tissue Homogenates, Serum, Biological Fluids, Plasma
  • Sensitivity: 75.0 pg/ml

OTHER RELATED ELISA KITS

TESTIMONIALS arrow icon

Your secretory IgA ELISA gave good results and I was also really impressed with how quickly we received it.

L. Johnston
PhD Student / University of Glasgow

It is refreshing to know that you have a technical team that is very knowledgeable. I have already recommended your company to other researchers in our department.

Dr. P. Anderson
Lecturer / University College London (UCL)

I am a first time user and found that your instruction manual was very easy to follow. The insulin ELISA assay performed well and I was happy with the results that were generated.

J. Thomas
Senior Technician / Addenbrooke’s Hospital

I carried out a pilot study comparing the performance of many ELISA assay's from different suppliers and found your kits to be one of the better performers. We observed good linearity and tight replicates.

Dr. C. Davies
Lead Scientists / AstraZeneca

You are my first point of contact when I am looking to purchase ELISA. You have such an easy and simple system, yet it is very effective.

A. Shaw
Purchasing / University of Oxford