COVID-19 (SARS-CoV-2) IgM ELISA Kit

INTENDED USE

Human COVID-19 (SARS-CoV-2) IgM ELISA kit is ideal for detecting amounts of human IgM antibodies to SARS-CoV-2 (COVID-19 IgM) using serum and plasma samples. Positive results have been shown to correspond to a 100% specificity.

BACKGROUND

A novel respiratory disease which later was called Coronavirus disease 19 (COVID-19) emerged from the city of Wuhan (China) and this rapidly spread within the country and also throughout the rest of the world. The genetic sequences for this virus displayed similarities to SAR-CoV and many other coronaviruses found in bats. It was found to be made up of several proteins which included: a nucleocapsid (N), spike (S), membrane (M) and an envelope (E). The transmission from one human to another human is through the generation of respiratory droplets via close contacts, coughing and sneezing. Symptoms of mild infection are: difficulty in breathing, fever, loss of taste, shortness of breath and coughing. For more serious infection this could lead to death, kidney failure and severe acute respiratory syndrome (SARS). Due to the nature of the virus it is extremely critical to use an effective detection procedure for analysing coronavirus. IgM represents the first immunoglobulin that is produced following a response to an antigen and is also predominately present during the early onset period of the disease. The following ELISA offers specificity, sensitivity and poses low risk during sample collection and handling.

COVID-19 IGM ELISA KIT CONTENT

All reagents supplied need to be stored at 2 °C – 8 °C, unopened reagents will retain reactivity until expiration date. Do not use reagents beyond this date.

  • SARS-CoV-2 Antigens Coated Microtiter Strips (IgM).
  • Positive Control (Calibrator C).
  • Cut-Off Standard (Calibrator B).
  • Negative Control (Calibrator A).
  • Enzyme Conjugate (IgM).
  • Sample Dilution Buffer.
  • Washing Buffer (20x Conc.).
  • TMB Substrate Solution.
  • Stop Solution.

SENSITIVITY

The minimum detection sensitivity level of human IgM against SARS-CoV-2 (COVID-19-IgM) using this COVID-19 IgM ELISA kit was to a specific cut-off point and a positive result was indicated by a 100% specificity.

ASSAY CHARACTERISTICS

– SARS-CoV-2 ELISA: IgM
– Negative: < 9 U
– Positive: > 11 U
– Cut-Off: 10 U
– Equivocal: 9 – 11 U
– Diagnostic Specificity: 100%
– Cross Reactivity: No significant evidence of false-positive results due to cross-reactions. However, cross reactions with antibodies to Respiratory syncytial virus cannot be excluded.

REFERENCES

  1. Delayed specific IgM antibody responses observed among COVID-19 patients with severe progression. Emerg Microbes Infect. (2020) 9 (1): 1096-1101. Shen L., et al.
  2. Serum IgM against SARS-CoV-2 correlates with in-hospital mortality in severe/critical patients with COVID-19 in Wuhan, China. Aging (Albany NY). (2020) 12 (13): 12432-12440. Liu X., et al.
  3. Rapid Detection of IgM Antibodies against the SARS-CoV-2 Virus via Colloidal Gold Nanoparticle-Based Lateral-Flow Assay. ACS Omega. (2020) 5 (21): 12550-12556. Huang C., et al.

ADDITIONAL INFORMATION

  • Full Name: COVID-19 (SARS-CoV-2) IgM ELISA Kit
  • Reactivity: Human
  • Sample Type: Plasma, Serum
  • Sensitivity: Cut-Off Point

OTHER RELATED ELISA KITS

TESTIMONIALS arrow icon

Your secretory IgA ELISA gave good results and I was also really impressed with how quickly we received it.

L. Johnston
PhD Student / University of Glasgow

It is refreshing to know that you have a technical team that is very knowledgeable. I have already recommended your company to other researchers in our department.

Dr. P. Anderson
Lecturer / University College London (UCL)

I am a first time user and found that your instruction manual was very easy to follow. The insulin ELISA assay performed well and I was happy with the results that were generated.

J. Thomas
Senior Technician / Addenbrooke’s Hospital

I carried out a pilot study comparing the performance of many ELISA assay's from different suppliers and found your kits to be one of the better performers. We observed good linearity and tight replicates.

Dr. C. Davies
Lead Scientists / AstraZeneca

You are my first point of contact when I am looking to purchase ELISA. You have such an easy and simple system, yet it is very effective.

A. Shaw
Purchasing / University of Oxford